I am not a University of Southampton researcher. Can I still access the facility?
Yes! The centre provides both academic and industrial consultancy services. We are working hard to provide accessible and top-quality X-Ray imaging services to a wide range of users. This includes external academic researchers and the industry.
Find out more here.
How much does a CT scan cost?
Beam-time is costed by session rather than "per scan" basis. Prices vary depending on the nature of the project; i.e. internal/external academic or industrial project. Representative figures are listed here and can be used for guidance. However, as each project presents unique technical challenges. Most of the times, especially when specimen type or geometry is nonstandard, we will perform trials/sanity checks in close consultation with users before funds are committed.
Please contact us with specific queries and we will be pleased to provide a quote.
How long does it take to acquire an scan?
Scanning times vary significantly. In principle it depends on the geometrical characteristics of the specimen, its material (electron density) and the system/hardware arrangement that needs to be used. Your scientific aim and objectives can also influence the scanning time. For example, one might need to limit scanning duration to "capture" time-critical processes for 4D-CT (e.g. S.D. Keyes et al.; scan duration 7 min per volume) in the expense of contrast or noise. Equally, when high resolution and low noise conditions are required for the analysis one might choose to increase scanning time (e.g. SM Yusuf et al.; scan duration 20 h per volume).
In general, scan duration can increase rapidly if resolution below 2-3 µm is sought, and/or underlying contrast is low (i.e. distinguishing subtle density changes in materials of similar atomic makeup). The following set of rules should be kept in mind:
Shorter scanning times can be achieved when
- the specimen is not very dense (e.g. polymeric materials)
- the features of interest within the specimen exhibit good density contrast against the surrounding matrix (e.g. air pores in organic matrix)
- the features of interest are fairly large in proportion to the overall size of the specimen (e.g. Smarties in candy tube)
Longer scanning times should be expected when
- the specimen is dense (e.g. rock, fossils, metals)
- the features of interest within the specimen exhibit poor density contrast against the surrounding matrix (e.g. soft tissue embeded in parafin wax)
- the features of interest are small in proportion to the overall size of the specimen (e.g. grains of sand in a 30 mm diameter core)
- low noise conditions are required
To get a more accurate scan-time estimate, please contact us to discuss your sample and imaging requirements.
Are there sample preparation and mounting requirements?
The sample should be mechanically stable and stationary, both inside and out, for the duration of the scan. Scan durations vary from a few minutes to many hours (see above). For most solid/rigid objects this is not an issue: samples containing liquid, visco-elastic, loose-packed powder or living material may require packing, physical support, cooling etc.
If the sample is to be kept within a container during scanning (e.g. to maintain moisture levels), it is best to minimise the density, thickness and external dimensions of the container. Simple polymer tubes/vials are ideal (e.g. see here). A conforming polymer wrap (cling film) can be ideal in self-supporting objects.
Samples MUST NOT shed any material (e.g. liquids or powder) into the CT equipment. If there is any risk, then some form of containment must be used.
What's the voxel resolution your scanners can achieve?
The range of equipment available in the centre allows a continuous voxel (3D pixel) size range that spans from hundreds of micrometres to hundreds of nanometres. However what's achievable in each case largely depends on the specimen.
A useful rule of thumb to find out the smallest voxel size achievable for a cuboid specimen scanned using a "default" imaging protocol is to measure its larger dimension (in mm) and divide that by 2000 or 3000 depending on equipment used. The result will be the voxel-size (in mm) of a scan using a 2000 x 2000 or 3000 x 3000 dexels detector respectively, with the entire specimen fitting tightly in the field of view.
However other, non-standard, acquisition techniques can push the envelope further.
If you are unsure as to what is possible with your specimens please get in contact with us to discuss your sample and imaging requirements.
What's the difference between Voxel resolution and Spatial resolution?
Voxel size acts as a form of "calibration" if the generated images, determined by the magnification factor of the imaging setup. It defines the physical length represented by each voxel (or pixel in a 2D slice). For example, if an imaging system has a voxel size of 1.65 μm, a feature measuring 20 voxels across would correspond to a real-world width of 33 μm.
Spatial resolution refers to the smallest detail (feature) that can be reliably distinguished in an image. While voxel size is an important factor, spatial resolution also depends on multiple other aspects of the imaging system, such as: [*] the X-ray source spot size; [*] the efficiency of any optical components (e.g., microscope objectives); [*] the signal-to-noise ratio; [*] the overall performance, setup and calibration of the system.
A common rule of thumb is that a feature needs to span at least 2.5 to 3 voxels (or pixels) to be reliably distinguished from noise. For precise measurements, dedicated quantitative methods exist to accurately assess spatial resolution.
Important Distinction: Spatial resolution should not be confused with contrast resolution. Spatial resolution determines the smallest details that can be discerned, while contrast resolution relates to the ability to differentiate between two materials with similar X-ray attenuation properties. The two factors interplay—high contrast can make small details more apparent, whereas poor contrast can obscure fine structures within the noise even if the spatial resolution is sufficient.
What's the biggest/heaviest specimen you can scan?
The largest field of view can be achieved by our custom walk-in scanning room (NXCT diondo d5) is in excess of 1x1x1.5 m and can support specimens up to 200 kg.
Do you accept all type of specimens?
We would scan most type of specimens our equipment can scan provided they are no safety and/or ethical issues associated with them. We always reserve the right to refuse scanning any specimen we think that might endanger the safety of personnel or equipment.
How can I submit a scan request and what do you need to know about my project?
If you are an internal or external academic user or Part III/MSc student wishing to submit a scan request please fill the appropriate "scan request" form located on this page. All we need to know is described in the form.
If you are an industrial customer please contact us directly
What kind of images are generated during CT data acquisition?
A set of 2-D images (usually called angular projections or radiographs) is captured at different angular positions as the sample is rotated during the scan. These projection images contain information about the attenuated X-ray beam, which passes through the sample.
Grey-scale values of pixels and their variation in angular projection images represent changes in the attenuation coefficient and therefore local density of the sample.
What kind of 3-D datasets are reconstructed from the set of 2-D radiographs?
An acquired set of 2-D angular projections is reconstructed into a 3-D rectangular grid composed of cuboidal building blocks known as voxels, which grey-scale values correspond to the linear attenuation coefficients of the sample material in these elementary volumes.
This 3-D volumetric map of linear attenuation coefficients can also be reconstructed as a stack of 2-D cross-sectional slices. CT reconstruction can be used for visualisation and quantification work, e.g. detection, extraction and measurement of features of interest. Volumetric datasets can also be converted into high-fidelity finite element meshes and CAD models.
What kind of data should I expect to find in my CT data folder?
A typical CT data folder contains [a] the raw projection data underlying the CT scan and [b] the raw reconstructed volume data (i.e. the "3D volume" file).
How can I acknowledge μ-VIS on my publication?
For the ongoing success and existence of the centre it is vital that our efforts are recognised.
The authors acknowledge the µ-VIS X-ray Imaging Centre (https://muvis.org), part of the National Facility for laboratory-based X-ray CT (nxct.ac.uk – EPSRC: EP/T02593X/1), at the University of Southampton for provision of tomographic imaging facilities.